Vy = Max{N1 + N3, N2 + N4} = 3831300N
承台斜截面受剪承载力按下列公式计算:
Vy ≤ βhs * βx * ft * byo * ho (基础规范 8.5.18-1)
Y 方向上自桩内边缘到最近柱边的水平距离:
ax = 750 - 0.5hc - 0.5bp = 750-800/2-433/2 = 133mm
λx = ax / ho = 133/(900-110) = 0.169
当 λx < 0.3 时,取 λx = 0.3
βx = 1.75 / (λx + 1.0) = 1.75/(0.3+1.0) = 1.346
βhs * βx * ft * byo * ho = 1*1.346*1.43*2500*790 = 3709561N
< Vy = 3831300N,满足要求。
4、柱下局部受压承载力计算:
局部荷载设计值 F = 7662600N
混凝土局部受压面积 Al = bc * hc = 560000mm
承台在柱下局部受压时的计算底面积按下列公式计算:
Ab = (bx + 2 * c) * (by + 2 * c)
c = Min{Cx, Cy, bx, by} = Min{850,900,800,700} = 700mm
Ab = (800+2*700)*(700+2*700) = 4620000mm
βl = Sqr(Ab / Al) = Sqr(4620000/560000) = 2.872
ω * βl * fcc * Al = 1.0*2.872*0.85*14.33*560000 = 19594014N
≥ F = 7662600N,满足要求。
5、桩局部受压承载力计算:
局部荷载设计值 F = Nmax + γg * Qgk = 1915.7+1.35*65 = 2003.4kN
混凝土局部受压面积 Al = π * d ^ 2 / 4 = 196350mm
承台在角桩局部受压时的计算底面积按下列公式计算:
Ab = (bx + 2 * c) * (by + 2 * c)
圆桩 bx = by = Sqr(Al) = 443mm
c = Min{Cx, Cy, bx, by} = Min{250,250,443,443} = 250mm
Ab = (443+2*250)*(443+2*250) = 889463mm
βl = Sqr(Ab / Al) = Sqr(889463/196350) = 2.128
ω * βl * fcc * Al = 1.0*2.128*0.85*14.33*196350 = 5090815N
≥ F = 2003417N,满足要求。
《主要参考文献和所用设计规范》
[1] 建筑设计资料集. 中国建筑工业出版社,1994.
[2] 教育部高等教育局. 高等学校毕业设计指导手册(土建卷). 高等教育出版社,1999.
[3] 《建筑结构荷载规范》(GB50009—2001),中国建筑工业出版社,2001.
[4] 《建筑结构制图标准》(GB/T50105-2001),中国建筑标准设计研究所出版,2001.
[5] 建筑结构构造资料集. 中国建筑工业出版社,2002.
[6] 《建筑地基基础设计规范》(GB50007-2002),中国建筑工业出版社,2002.
[7] 梁兴文、史庆轩主编. 土木工程专业毕业设计指导. 北京:科学出版社,2002
[8] 丰定国, 王杜良. 抗震结构设计. 武汉工业大学出版社,2003.
[9] 《混凝土结构施工图平面整体表示方法制图规则和构造详图》(图集号03G101-1),中国建筑标准设计研究所出版,2003.
[10] 东南大学等. 混凝土结构. 中国建筑工业出版社,2003.
- 上一篇:应用Fluent的UDF二次开发对某隧道安全通风进行设计