lastly,we observing its internal working condition。 Through observation, It is found that when filling amount is 30% for the first time,It is found no pool boiling phenomenon, but we can observe the phenomenon of drying up from the wicks center to periphery。The evaporation model is liquid membrane evaporation。 Change the charging rate to 100%,and the heat flux density of less than 11W/cm2, it is found no apparent air bubbles, namely no pool boiling phenomenon, the evaporation model is liquid membrane evaporation too。 And when continue increase heat flux density, we can see the pool boiling phenomena。 In the porosity wicks, we can observe the pulsation phenomenon。This shows that under low charging rate and low heating power, its internal state mainly keep liquid membrane evaporation, not as we usually think of that pool boiling phenomenon; When reaches a certain liquid rate and a certain heating power, pool boiling phenomenon can only be seen。
Keywords: Vapor chamber;Form copper; pool boiling phenomenon; Visualization
目 录
第一章 绪论 1
1。1 课题背景 1
1。2 均温板简介 1
1。4 均温板机理研究现状 7
1。5 本课题的主要研究内容 9
第二章 均温板实验系统设计 10
2。1 实验台的设计 10
2。2 均温板的设计 13
2。2。1 均温板上下板的设计 13
2。2。2 吸液芯的选择 15
2。2。3 工质的选择与充液率 15
2。3 可视化实验系统设计 16
2。3。1 可视化加热、保温与冷却系统设计 16
2。3。2 可视化均温板设计 17
2。4 均温板的制备 18
2。4。1 泡沫铜吸液芯 18
2。4。2 均温板的清洗 19
2。4。3 焊接 21
2。4。4 充注与抽真空 21
2。4。5 焊接封口 22
2。4。6 可视化均温板的制备 22
2。5 均温板实验测量系统 23
2。5。1 热电偶的标定与布置 23
2。5。2 测试结果计算基本公式 24
2。5。3 实验系统的误差 25
2。6 本章小结 26
第三章 可视化实验测试与分析 28
3。1 可视化测试系统 28
3。2 测试结果分析 28
3。2。1 100%充液率的实验分析 28
3。2 本章小结 34
结 论 38
致 谢 39
`参考文献 40
第一章 绪论
1。1 课题背景
近些年来,越来越多的电子产品都有往高性能、微小化走的趋势。几乎所有的 电子元器件单位容积的发热功率以及热流密度都大幅跃升,这必然造成其热应力的 增加以及温度水平的升高[1]。电力电子装置的工作最佳温度是零下 5℃至 70℃,若温 度不在这个范围内,运行设备的电子器件就会出现异常,该设备的工作寿命以及可 靠性会受到极大的影响[2]。因此,解决散热问题已成为近年电子产品的设计重点之一。论文网