摘要本论文主要针对新型智能化超微心电图展开相关设计的工作,通过对心电信号的特点以及复杂的噪声环境,以及对传统心电设备的前置放大电路进行认真的研究,确定了基于锁定放大技术的前置放大器的设计方案。该设计方案能够有效滤除混叠在心电信号中的噪声,放大有效信号。实现了较高的信噪比及低失真度,高质量地完成了窦房结电图的信号获取与数据采集。61405
毕业论文关键词 窦房结电图,锁定放大器,信噪比
毕业设计说明书(论文)外文摘要
Title The intelligent and ultra-micro ECG The design of pre-amplifier
Abstract The dissertation carry out design work related for The intelligent and ultra-micro electrocardiogram (ECG).On serious analysis of the feature of the ECG,the complicated Noise Environment and the pre-amplifier of traditional ECG device,the dissertation utilize a new design basing on the Lock-in Amplifier. This pre-amplifier can filter out the noise included in the ECG signal ,and amplify the useful signal. this design achieve high Signal-to-Noise ratio and low distortion factor. And the pre-amplifier achieve obtaining the SNE signal with high quality.
Keywords SNE ,Lock-in amplifiers ,signal-to-noise ratio
目 录
1 绪论 1
1.1 课题背景及意义 1
1.2 心电前置放大技术的国内外发展状况 1
1.3 心电前置放大技术的发展趋势 2
2 心电前置放大电路的设计 3
2.1 SNE(窦房结电图)前置放大器的设计 3
2.2 ECG(心电图)前置放大器的设计 21
3 实验与调试 30
3.1 实物电路图 30
3.2 实验部分 31
结论 37
致谢 38
参考文献 39
1 绪论
1.1 课题背景及意义
超微心电图仪(Ultra-Micro Electrocardiograph—— UMECG)是能够直接从体表记录窦房结电图(Body surface Sinus Node Electrogram—SNEb)的高分辨率心电图。心脏窦房结是心脏跳动的动力源点,它就像一个发电站,是心脏跳动的启动器(细胞),正常的心律都是由窦房结的激动导致的,窦房结的病变,是心律失常发生的主要原因之一。窦房结电图是评估窦房结功能的最直接依据,如何安全精确的获得窦房结电图是国内外研究的热点问题。文献综述
超微心电图仪的核心关键在于窦房结电图前置放大器,其作用是将微弱的窦房结电信号高保真放大以便后续数据采集、显示和分析之用。随着临床医学对超微心电图仪要求的日益提高,目前采用的SNEb前置放大器存在基线稳定技术、噪声抑制技术方面的不足,基于原有SNEb前置放大器的技术方案难以克服上述不足,为此,必须采用新原理研制新型SNEb前置放大器,解决上述问题,提高 SNEb的记录水平,提升超微心电图仪的品质。
1.2 心电前置放大技术的国内外发展状况
1.3 心电前置放大技术的发展趋势
2 心电前置放大电路的设计源:自'优尔.·论,文;网·www.youerw.com/
2.1 SNE(窦房结电图)前置放大器的设计
SNE的设计主要采用锁定放大器,其中包括了输入保护电路,屏蔽驱动电路,右腿驱动电路,差分放大电路,信号调制电路,1mv定标电路,带通滤波电路,工频陷波电路,相敏检测电路,RC移相电路,低通滤波电路,倍数切换电路等。