摘要大容量发电机的造价昂贵,结构复杂,一旦发生故障遭到破坏,其检修难度大,检修时间长,要造成很大的经济损失,大机组在电力系统内占有重要地位,特别是单机容量占系统容量很大比例的情况下,机组的突然切除,会对电力系统造成很大的扰动。64227

    为了满足电力系统稳定方面的要求,对于发变组故障时要求继电保护满足可靠性、灵敏性、选择性和速动性来故障切除。从而提高了发电机和变压器的保护配置合理性、整定计算原则的全面性和整定计算结果准确性的要求。本文首先,根据一次系统图及相应等效电抗图,计算相应的短路电流,为后期的保护整定提供数据依据。然后,分别对发电机和变压器进行了合理、规范的保护配置和整理各保护的整定原则。最后,对发变组中各保护的整定原则进行了详细的分析,对发电机配置的差动保护、对称过负荷保护、不对称过负荷保护、失磁保护、失步保护、启停机等保护,主变配置的差动保护、过励磁保护、零序保护、复压过流保护和非电量等保护进行了详细的整定计算,并结合灵敏度的要求得到了发变组各保护合理的整定定值。整定结果表明,本文提出的保护配置和整定方案适用于大容量机组发电机变压器的保护,可有效的规范大容量机组发电机、变压器的保护配置和整定计算。

毕业论文关键词  保护配置,继电保护,整定计算,电力系统

毕业设计说明书(论文)外文摘要

Title    Large capacity generator relay protection setting calculation                                                                        

Abstract Large generators are expensive and the structure are complex,once destroyed, it is difficult and takes a long time for overhaul,causing great economic losses. Large units in the power system plays an important role within, especially in stand-alone capacity accounting system capacity a large percentage of cases, the sudden removal of large units, will cause great power system disturbances.

In order to meet the requirements of power system stabilizer, for transformer unit fails to meet the reliability requirements of protection, sensitivity, selectivity and speed and mobility to fault clearing.Thereby increasing the generator and transformer protection configuration rationality, setting calculation principles of comprehensiveness and accuracy of the results setting calculation requirements.Firstly, according to a system diagram and the corresponding equivalent reactance diagram, calculate the corresponding short-circuit current protection setting for the latter to provide the data basis.Then, respectively,configurate protection of the generators and transformers\ reasonable and standardized,and finishing setting the principle of each protection.Finally, each transformer unit protection setting principles for a detailed analysis of the configuration of the generator differential protection, overload protection symmetrical, asymmetrical overload protection, loss protection, stall protection, Kai shut-down protection main transformer differential protection configuration, overexcitation protection, zero-sequence protection, overcurrent protection and non-power complex pressure and other protection, and high plant configuration variable differential protection, overcurrent protection and non-power complex pressure such protection were detailed setting calculation, combined with sensitivity requirements have been the transformer unit protection setting a reasonable value.Tuning results show that the proposed protection configuration and tuning program for large capacity unit generator transformer protection, can effectively regulate large capacity units generator, transformer protection configuration and setting calculation.

上一篇:MATLAB风资源评估系统的开发与应用
下一篇:LQR振动控制的独立模态空间控制方法设计

风力发电机组齿轮箱概述【3352字】

试论某电厂2×300MW机组凝结...

试析电力系统继电保护装...

继电保护茬电力系统中的...

电力自动化继电保护安全...

电力自动化继电保护安全管理探讨【2224字】

电力继电保护的电工维修技术研究【2457字】

ASP.net+sqlserver企业设备管理系统设计与开发

张洁小说《无字》中的女性意识

LiMn1-xFexPO4正极材料合成及充放电性能研究

我国风险投资的发展现状问题及对策分析

老年2型糖尿病患者运动疗...

安康汉江网讯

新課改下小學语文洧效阅...

麦秸秆还田和沼液灌溉对...

互联网教育”变革路径研究进展【7972字】

网络语言“XX体”研究